UV Curing Light Measurement

ILT UV Curing-Specific Systems

Curing a product with exposure to UV light, while fast and economical, requires careful control of the exposure process such as the spectral output of the light source, intensity levels, and exposure times of the products.

International Light Technologies has developed a broad range of UV curing-specific systems to aid in the challenging task of defining and monitoring these process variables. The systems are listed in the table below - CLICK ON THE ILT PART NUMBER IN THE "ILT SYSTEM OPTIONS" COLUMN TO SEE SPECIFIC SYSTEM DETAILS.

 
General
Application
Specific
UV Curing
Applications
Spectral Range ILT System Options
Click Links Below
Measurement Range Units
CURING
UV Oven/
Belt Radiometer
270-475 nm ILT400BAV 1 mJ to 20 J/cm² W/cm² & J/cm²


315-390 nm ILT400UVA 1 mJ to 20 J/cm² W/cm² & J/cm²


390-475 nm ILT400UVV 1 mJ to 20 J/cm² W/cm² & J/cm²


250-400 nm ILT490 1 mJ to 20 J/cm² W/cm² & J/cm²


205-345 nm ILT490C 1 mJ to 20 J/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Broadband UV
250-400 nm IL1700, SED005/WBS320/W 2.33e-9 to 2.33e+0 W/cm² W/cm² & J/cm²


250-400 nm IL1400, SEL005/WBS320/TD 1.82e-7 to 6.36e-1 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Narrowband 335
330-340 nm IL1700, SED005/NS335/W 1.00e-8 to 1.00e+1 W/cm² W/cm² & J/cm²


330-340 nm IL1400, SEL005/NS335/TD 2.33e-6 to 8.14e+0 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Xenon Flash 326-401 nm IL1700, SED033/B/QNDS2/W 5.70e-8 to 5.70e+1 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Low profile high UV 250-400 nm IL1700, SED005/WBS320/RAMP18 8.00e-6 to 1.00e+1 W/cm² W/cm² & J/cm²


250-400 nm IL1400, SEL005/WBS320/RAMP18 4.00e-4 to 1.00e+1 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Low profile low UV 250-400 nm IL1700, SSD001A 2.22e-7 to 9.00e-1 W/cm² W/cm² & J/cm²


250-400 nm IL1400, SSL001A 1.11e-5 to 9.00e-1 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Low profile Spot-Cure 320-400 nm IL1700, XRD050 1.82e-7 to 1.82e+2 W/cm² W/cm² & J/cm²

Low profile Spot-Cure 320-400 nm IL1400, XRL050 9.09e-6 to 3.18e+1 W/cm² W/cm² & J/cm²
========== ====== ====== ========== ====== ======

Dental curing 370-515 nm IL1700, SED033/TBLU/T1MM 1.30e-7 to 1.29e+1 W/cm 2 W/cm² & J/cm²


370-515 nm IL1400, SEL033/TBLU/T1MM 6.45e-6 to 2.26e+1 W/cm 2 W/cm² & J/cm²
========== ====== ====== ========== ====== ======
* All Radiometers/Photometers/Spectroradiometers are NIST Traceable.

* If units of measure are not shown, contact ILT (empirical units also available i.e. fc, fL, nits, lm/ft²).