Accessories
—
filed under:
light measurement accessories,
light detection,
light measurement,
detectors,
accessories,
input optics,
cables
|
International Light Technologies offers a wide variety of accessories including tripods, power cords, computer and extension cables, cases and underwater sensor modifications.Please refer to the chart below for a list of the standard, stock accessories. If you have a requirement for a custom accessory that you can not locate in the list below please contact our engineering dept for further assistance. |
![]() |
| Part Number | Description | Specifications |
|---|---|---|
| A26 | Sunglasses | Prevents eye damage by blocking UV and IR radiation. |
| A204 |
Small Tripod | Adjustable tripod for use with
RPS900-C and SED sensors ¼-20 UNC |
| A205 | Bench Post | Adjustable post with base for use on or off optical benches. |
| A250 | Port Adapter | Test light source fixture for use with the INS250 Integrating Sphere allows a light source to be measured in the integrating sphere to easily be wired to an external power source without measurement interference. |
| A405 | Carrying Case for IL1700 &A415 | For ILT1700, A415 and/or detectors and accessories |
| A406 | Cable | Adapter Cable: SEE Detector To ILT1700 |
| A407 | Cable | 10' Extension Cable For SED Detectors |
| A411 | Cable | Adapter Cable: SEL Detector To ILT1700 |
| A412 | Cable, IL1700 RS232 w/DB25 | RS232C Cable, Ten Feet, Male-Female |
| A413 | Cable, RS232 | RS232C Cable, Ten Feet, Male-Male |
| A417 | AC operated battery option | Includes internal battery charger, with 6 installed and charged rechargeable Ni-Cad batteries. |
| A425 | Oscilloscope adapter, DB15 to wire | Current to Voltage converter/adapter connects "D" type (ILT1700) detectors to Oscilloscopes, volt meters, data loggers, and computers. Recommended for use with solid-state SED type (SED033, SED005, and SED007), SPD, and XRD type two-wire detectors only. SED185, 220, and 240 phototube
detectors and SED623, 624, and 625 thermopile detectors require additional power supply connections not provided by the A425 adapter. PLEASE NOTE: Low level light signals require that the voltage measuring instrument have sufficient sensitivity and resolution to measure the small resulting voltages. |
| A430 | Detector Amplifier | 0-5 V low impedance output to provide interface between
low level detector currents and the low impedance voltage receiving
equipment. Connector for SEL type detectors only. All other will
require adapter (A508) or hard wiring. The A430 Detector Amplifier is
intended for use with solid-state SEL033, SEL005, and SEL007 two-wire
detectors only. SEL185, 220, and 240 phototube detectors and SEL623, 624, and 625
thermopile detectors require additional power supply connections not provided by the A430 amplifier. A430 Manual |
| A440 | Cable, IL1700 RS232C w/DB9 | Cable, ILT1700 RS232C w/DB9 |
| A507 | Cable, extension | 10' Extension Cable For SEL / SL Detectors |
| A508 | Cable | SED Detector To ILT1400A |
| A510 | Cable, RS232 /detector | ILT1400 Y-shaped cable connects to computer and detector. |
| A511 | Cable, RS232 /detector | ILT1400 Y-shaped cable connects to computer and detector w/DB9 serial connector. |
| A512 |
Cable, USB /detector | ILT1400 cable connects to computer and detector w/USB plug. Please Note: It is necessary to download and install the Virtual COM Port Driver prior to connecting A512 to computer for A512 to work properly. Driver supports Windows XP and Windows 7. Installation of drivers is automatic when you run the setup program. Links: A512 Virtual COM Port Driver A512 Instruction Manual |
| A516 | ILT1400 A/C power cord | A/C power cable for 120 V. |
| A525 | Oscilloscope adapter,20pin card edge | Current to Voltage converter/adapter connects "L" type (ILT1400) detectors to Oscilloscopes, volt meters, data loggers, and computers. Recommended for use with solid-state SEL type (SEL033, SEL100, SEL005,
and SEL007), SPL, and XRL type two-wire detectors only. SEL185, 220, and 240 phototube
detectors and SEL623, 624, and 625 thermopile detectors require
additional power supply connections not provided by the A525 adapter. PLEASE NOTE: Low-level light signals require that the voltage measuring instrument have sufficient sensitivity and resolution to measure the small resulting voltages. |
| A602 | Cable, MiniDin6 M/M blk 12ft. | MiniDin6M/M blk 12ft. |
| A603 | Cable, MiniDin6 M/StpLead blk 6ft | MiniDin6 M/StpLead blk 6ft |
| A803 | Multiplexer/Datalogger |
Converts ILT1700 Research Radiometer into a multi-input data-logging radiometer for long-term, continuous monitoring and light measurement data collection from up to eight (8) ILT detectors. |
| CC390 | Carrying Case, IL290 - IL393 | For IL390C, IL393, and IL290A |
| CC500 | Carrying Case: ILT1400,TREC1600 | For ILT1400A, IL70 and TREC 1600 |
| PUBXXXX | MANUALS | ILT-1400, 1700, 393, 390, 70 and RPS-900, 380, 200 Manuals |
| RPS-HP | Notebook Computer | for use with RPS spectroradiometers. Comes complete with all RPS software installed. |
| SUD(SUL)XXX | Underwater Detector Modification | Underwater version of SED(SEL)XXX/W Detectors. Includes 100 feet of cable with waterproof housing and pressure tested to 100 foot depths. (W required). |