A803 Multiplexer/Datalogger

A803 Multiplexer / Datalogger converts ILT1700 Research Radiometer into a multi-input data-logging radiometer for long-term, continuous monitoring and light measurement data collection from up to eight (8) ILT detectors.

  • For use with ILT1700 to monitor and record data from 1 to 8 ILT detectors (example system configurations by application listed below)
  • Rapidly change between detectors via software (included) or manually using the active channel buttons
  • Data log up to 2 billion data points with time and date stamp
  • 10 Decade Dynamic Range
  • Programmable units of measurement include lux, W/cm2, Watts, candela, many others
  • Remote control of many ILT1700 features including Hold, Zero, DC and Integrate
  • Software displays light measurements in real-time
  • Export data into most standard analysis software such as Microsoft Excel®
  • National Instruments LabView® interface/driver that allows customization is available
A803 8 Channel Multiplexer with ILT1700 Laptop and 3 Detectors

Photo: A803, ILT1700, PC & 3 ILT Detectors
(Click on photo to see larger image)

 

The ILT Model A803 is designed to provide the ILT1700 Research Radiometer with the ability to continuously monitor and collect light measurement data from up to eight (8) ILT detectors. Many combinations of ILT detectors up to eight total may be used and can be remotely mounted with custom cable lengths up to 100 feet in length.

Use of the A803 with the ILT1700 Research Radiometer eliminates the need to manually change detectors and calibration factors. The A803 software records the channel and calibration factor and allows the researcher to quickly change between detectors without having to unplug and exchange detectors on the rear panel of the ILT1700. This reduces the risk of using the wrong calibration factor and decreases the set-up time. It also allows user control of functionality of the ILT1700 including, zero, hold, integrate and DC mode selection.

A803 Special Pricing Offers

For a limited time, ILT is providing special package pricing for A803 purchases that include either a new ILT1700 or retrofitting an existing ILT1700 with a USB connector.  Please contact Jill Fowler, ILT Systems Sales Manager, for details and pricing.

 

The included software can display data in real-time and easily export to text or spreadsheet for further analysis in external software.

 

 

 

 

 

 

 

 

 A803 Software Screen Shot

Photo: A803 Software Screen Shot
(Click on photo to see larger image)

 

A803-8 Front Panel

  • Function control panel indicates ILT1700 features zero, dc, integrate and hold
  • Active Channel buttons manually switch between detectors
  • LED channel indicators show which detector is in use

 

A803 Front Panel

 

A803-8 Back Panel

  • 8 detector ports for sensor connection
  • USB port connects to computer
  • Accessory input allows control of ILT1700 functions

 

 

A803 Back Panel

 

Configuration Information:

Optimum system configuration: A803, ILT1700, personal computer (laptop or desktop) and up to 8 ILT detectors.

Two Model ILT A803 configurations are available:

A803-8 (8 detector channels)

A803-4 (4 channels)

 

Technical Information

A803 Datasheet (PDF)

A803 Operator Manual (PDF)

 

Specifications:

Input: Up to 8 ILT detectors
Output: USB 2.0
Dimensions: 2.625" x 7.5" x 4.625"
Weight: 1.75 lbs
Data Acquisition Rate: 0.5 seconds to 12 hours
Computer Requirements:
Operating System: Windows XP, Vista, 7
Data Output: Excel (.xls) or Text (.txt)

 

Example A803/ILT1700/Detector System Configurations by Application:


GERMICIDAL, HIGH INTENSITY, LOW PRESSURE MERCURY DETECTOR
Specifically designed to measure high intensity low-pressure mercury lamps at 254 nm.
System Configuration: A803, ILT1700, Detector: SED008/W, Range: 2 e-7 to 1 E+2 W/cm²

GERMICIDAL, LOW-PROFILE, HIGH-INTENSITY GERMICIDAL DETECTOR
Filtered for measurement of 254 nm for narrow and broad spectrum lamps, in a low profile housing for versatility.
System Configuration: A803, ILT1700, Detector: XRD140T254, Range: 7e-9 to 6e+0 W/cm²

PHOTODEGRADATION / PHOTOSTABILITY MAPPING
UVA AND VISIBLE (WHITE) LIGHT TEST SYSTEM
Measurement of UVA in W/m² and VIS in Lux for long term testing and datalogging during degradation studies.
System Configuration: A803, ILT1700, Detectors: SED033/UVA/TD, 5e-6 to 5e+3 W/m² and SED033/Y/TD, 5.98e-2 to 2.09e+5 lux.

SOLAR MEASUREMENT, UVA and UVB
For solar measurements of UVA and UVB from the sun or solar simulators. These sensors have been selected for the improved out-of-band rejection. Additional sensors for Broadband, Visible and IR regions are also available.
System Configuration: **A803, ILT1700, Detectors: SED005/UVA/TD, 5e-9 to 4e+0 W/cm² and SED240/UVB/SPS300/T/W, 4e-8 to 2e-2 W/cm²

PHOTOTHERAPY, UVA and UVB
For rapid testing of UV irradiance levels during patient exposure.
System Configuration: **A803, ILT1700, Detectors: SED033/UVA/W, 3e-10 to 2e-1 W/cm² and SED240/UVB-1/W, 2e-7 to 6e-2 W/cm²

PLANT GROWTH / PHOTOBIOLOGY
For measurement of Photosynthetically Active Radiation, Blue light, Red light and Far red light levels to test the affects on plant growth.
System Configuration: A803, ILT1700, Detectors: SED033/PAR/W, 5e-10 to 5e-1 uE/cm²/sec; SED033/TBLU/W, 3e-10 to 2e-1 W/cm²; SED033/TRED/W, 2e-10 to 1e-1 W/cm²; SED033/TFRD/W, 1.47e-10 to 1.47e-1

 

** Configuration requires multiple detector biases - contact ILT Sales before ordering.

 