All precision light measurement instruments and their detectors, such as our ILT1400 and ILT1700 Light Meters, require periodic recalibration to ensure proper operation. That is why International Light Technologies has expanded our NIST traceable calibration lab and invested in new equipment.

ILT has also extended our calibration service offering to include calibration of non-ILT light measurement meters and systems (see part numbers beginning with "C" below).

Calibration Lab

As our customer base has grown over the past 40+ years, and as our customers have adopted quality manufacturing standards such as ISO17025 and ISO9001, we have seen a dramatic increase in the demand for annual NIST traceable recalibration. In response to this increase in demand for calibration services we have expanded our calibration lab, invested in new equipment, and are planning to extend our standard calibration service offering.

Annual Re-calibration

All instrumentation requires periodic re-calibration to ensure proper operation. In addition, extreme operating conditions (UV, heat, and dirt) can degrade optical performance potentially requiring an increase in re-calibration frequency. Annual re-calibration provides a relatively inexpensive guarantee of accuracy. Accurate readings translate into more efficient production processes, more reliable research and safer medical procedures.

NIST Traceable

International Light Technologies obtains fully characterized Primary Standard Detectors directly from the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. Through the transfer of standards technique, we compare the output of a customer's detector to a standard under tightly controlled laboratory conditions.

Link to ISO/IEC 17025:2005 Accreditation and ISO9001:2008 Certification Information

ILT Calibration Lab

The list below describes the basic types of optical calibrations that we perform in our metrology lab. All instrumentation requires periodic recalibration to ensure proper operation. The PIR and YIS calibrations are our most commonly requested calibrations for radiometers and photometers, respectively. Our flexible laboratory setup allows us to perform a wide range of different calibrations at a reasonable cost.

Calibrations

Calibration PRICES are NOT listed on this Web site - please Contact ILT Sales for calibration prices.

Part Number

Description

Specifications

ECAL/1400

ILT1400 Radiometer Electrical

Electrical accuracy and linearity check, and recalibration to NIST standards. Includes I/O check.

ECAL/1700

ILT1700 Radiometer Electrical

Electrical accuracy and linearity check, and recalibration to NIST standards. Includes I/O check.

ECAL/METER

ILT Obsolete Radiometer Electrical

Electrical accuracy and linearity check, and recalibration to NIST standards. Includes I/O check.

BIR(IBIR)

Band Irradiance Response

Band Irradiance response, (amps)(cm²)(nm)(watt-1), of an ILT bilirubin detector

CSAR

Custom Scanned Absolute Response

Same as a SAR for other than an ILT sensor assembly or electro-optical system. Standard wavelength coverage is 250-1000 nm.

CSIM

Custom Spectral Irradiance

Spectral irradiance response of light source.

CSPR

Custom Single Point Calibration

Optical Calibration of Non-ILT Light Measuring Instrumentation.

Items must be sent in full working condition. Single point optical calibrations are performed at the peak or center wavelength of the sensor combination in empirical units such as W, W/cm2, Cd, lumens, Lux etc. No repairs or adjustments are made on the unit.

A calibration certificate with a reading correction factor is provided. Copy of a sample certificate is available upon request. Please contact an ILT representative for approval and fill out a RMA (Return Material Authorization) prior to shipping any items to ILT.

CYINS

Custom Calibration for NON ILT Lux Meters

Special Price: $260 (US)

Optical Calibration of Non-ILT Low Cost Lux Meters.

Calibration in Fc or lux for low cost, hand-held lux meters not manufactured by ILT including Extech, Solar Light, Cooke.

Calibration correction factor provided with a NIST traceable and ISO 17025 accredited calibration and certificate (no internal adjustments are made to the meter).

Copy of a sample certificate is available upon request. Please contact an ILT representative for approval and fill out a RMA (Return Material Authorization) prior to shipping any items to ILT.

CSTM

Custom Spectral Transmission

Plot of percent transmission vs. wavelength (nm) for any filter.

IEO

System Calibration

Calibration of ILT70-based Radiometer Systems. Includes 9V battery replacement, electrical test and optical recalibration for direct readout in the appropriate optical units.

IEC

ILT400 & ILT490 Belt Radiometer Calibrations

Electrical test and optical recalibration for direct readout in appropriate optical units for ILT400 and ILT490 Belt Radiometers

IER

Belt Radiometer Calibration

Calibration of ILT290,ILT390, and ILT393 systems. Includes battery replacement, UV filter, electrical test and optical recalibration for readout in mJ/cm².

PINR(IPINR)

Peak Intensity Response

Intensity response, (amps)(sr)(watt-1), at peak sensitivity of IL detector.

PIR(IPIR)

Peak Irradiance Response

Irradiance response, (amps)(cm²)(watt-1), at peak sensitivity of an IL detector.

PIRE(IPIRE)

MicroEinsteins/sec/cm²

Same as PIR but for readout in microEinsteins/sec/cm².

PPR(IPPR)

Peak Power Response

Power response, (amps)(watt-1), at peak sensitivity of an IL detector.

PRR(IPRR)

Peak Radiance Response

Radiance response, (amps)(cm²)(sr)(watt-1), at peak sensitivity of an ILT detector.

SAP

Scanned Absolute Power Response

Scan with tabulated data of absolute power response, (amps)(watt-1) vs. nm, of an ILT detector. (250-1000 nm)

SAR

Scanned Absolute Response

Scan with tabulated data of absolute irradiance response, (amps)(cm²)(watt-1) vs.nm, of an ILT detector. (250-1000 nm)

SARE

Scanned Response, Einstein

Scan with tabulated data of absolute irradiance response, microEinsteins/sec/cm² vs. nm, of an ILT detector. (250-1000 nm)

SAXT

Extended Scanned Calibration

Service to expand calibration below 250 nm (down to 200 nm) or above 1000 nm (out to 1100 nm with NIST traceability, or out to 1600 nm without traceability).  Purchase of standard scan from 250-1000 nm required.

SRAD

Scanned Absolute Radiance Response

Scan with tabulated data of absolute radiance response, (amps)(cm²)(sr)(watt-1) vs.nm, of an ILT detector. (250-1000 nm)

SIR

Spectral Irradiance Response

Scan with tabulated data, (amps)(cm²)(nm)(watt-1) vs.nm, of all obsolete versions ILT spectroradiometers. (250-1000 nm)

SOL(ISOL)

Solar UVB Response

Irradiance response as compared to simulated solar UVB spectral irradiance integrated below 315 nm, for an ILT UVB detector.

SRR

Scanned Relative Response

Scan with relative response data (% vs. nm), of an ILT detector. (250-1000 nm)

SUV

Extended UV Scanned Calibration

Scanned UV calibration every 2 nm from 200-400 nm.

VS1, VS2

Scanned Absolute Radiance Response

ILT380 and ILT200 Spectroradiometer calibration includes certification and CD with calibration data.

VS9

Spectroradiometer Calibration

ILT900 spectroradiometer calibration from 250-950 nm. Includes certification and CD with calibration data.

WIRA

Wide Irradiance Response

Wide Irradiance Response (amps)(m²)(watt-1) as compared to an extended area UVA source, spectrum integrated from 315-400 nm.

WIRX

Wide Irradiance Response

Wide Irradiance Response (amps)(m²)(watt-1) as compared to Xenon ID65 or Xenon Glass window source (Select one), spectrum integrated from 315-400 nm.

XIR(IXIR)

Custom PIR at specified wavelength

Irradiance response, (amps)(cm²)(watt-1), at specified wavelength X, within the bandwidth of an IL detector.

XPR(IXPR)

Custom PPR at specified wavelength

Radiance response, (amps)(watt-1), at specified wavelength X, within the bandwidth of an ILT detector.

XRR(IXRR)

Custom PRR at specified wavelength

Radiance response, (amps)(cm²)(sr)(watt-1), at specified wavelength X, within the bandwidth of an ILT detector.

YFS(IYFS)

Photopic Flux Sensitivity

Total photopic flux response, (amps)(lumen-1), of an ILT photopic detector.

YIN

Standard INS250 Lamp Intensity

Mean spherical candle power output of INS250 integrating sphere lamp.

EYINS(IEYINS)

Effective Photopic Intensity Sensitivity

Effective photopic intensity response, (amp)(eff. candela-1), of an ILT photopic detector for flash measurements.

YINS(IYINS)

Photopic Intensity Sensitivity

Photopic intensity response, (amp)(candela-1), of an ILT photopic detector.

YIS(IYIS)

Photometric (Y) Illuminance Sensitivity

Illuminance sensitivity, (amps)(ft2)(lm-1) or (amps)(m2)(lm-1), of an ILT photopic detector.

YCL(IYCL)

Photometric (Y) Contact Luminance Sensitivity

Luminance sensitivity, (amps)(fL-1) or (amps)(m2)(cd-1), of an ILT photopic detector.

YCOL

Photometric Color Correction

Modified photometric calibration at customer specified color temperature, intensity or wavelength.

YLS(IYLS)

Photometric (Y) Luminance Sensitivity

Luminance sensitivity, (amps)(fL-1) or (amps)(m2)(cd-1), of an ILT photopic detector.

YSAR

Scanned Absolute Illuminance Response

Scan with tabulated data of absolute illuminance response, (amps)(f+2)(lm-1) vs. nm or (amps)(m2)(lm-1) vs. nm, of an ILT photopic or scotopic detector.

ZIS(IZIS)

Scotopic Illuminance Sensitivity

Illuminance sensitivity, (amps)(ft2)(lm-1) or (amps)(m2)(lm-1), of an ILT scotopic detector.

ZLS(IZLS)

Scotopic Luminance Sensitivity

Luminance sensitivity, (amps)(fL-1) or (amps)(m2)(cd-1), of an ILT scotopic detector.

Express Service

3 Day Priority Calibration

3 – 5 day priority service for a maximum of 2 systems (maximum 2 calibrations per system). Additional items will be an extra $25.00 US each.  No guarantee is implied. No express charge will be incurred if ILT cannot ship within 5 business days (excludes repairs and scanned calibrations). Availability of service is dependent on calibration schedule.

Repairs

RPR/PARTS and RPS/LABOR

All repairs are billed per hour plus parts. Repairs are no longer available for obsolete equipment.


All calibrations are performed under controlled environmental conditions.
 

All calibration and repair service orders MUST have a Return Authorization (RA) number referenced on the packaging and/or the packing list PRIOR to return shipment to ILT for service. Equipment received without a RA number will be placed on hold upon arrival pending approval for service charges. To obtain an RA number, please fill out our Return Authorization form - you will automatically receive an RA# once the form is submitted.

Please note: All calibrations are performed in the order they are received into service. Express Service orders are given priority over standard calibration orders where possible but in the event that multiple Express Service orders are in-house at the same time - Express Service orders are done in the order they were received into service. Express Service orders are subject to availability and exclude repairs and scanned calibrations. Express Service order delivery times are not guaranteed. All orders are subject to a $65 min evaluation fee. Cancelled/changed orders will be billed for any completed calibration at the time of cancellation/change, and a minimum evaluation fee of $65 if no calibrations have been performed.

If your are returning light measurement instrumentation to ILT for repair service, please review our Troubleshooting Guide prior to filling our the Return Authorization Form.

All calibration orders are subject to the following Terms and Conditions