ILT1700, SED033/SCS395/TBLU/R

Bench-top research "Blue Hazard" radiance system

View ILT5000 Replacement
 

*** DISCONTINUED ***

The ILT1700 has been replaced the ILT5000 Radiometer which includes complimentary Datalight III software, faster measurement speeds, wireless data transmission, iPhone/iPad application, internal data storage, a broader measurement range and more…

 

ILT5000 Features

Bench-Top Research "Blue Hazard" Radiance System

  • 10+ Decade Dynamic Range of Optical Analysis
  • Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
  • Wireless Communication, Built-in
  • User controlled or Auto: Range, Zero/Dark, Sample Rate
  • 4-20 mA Output
  • 15 pin D Sub and SMA sensor/input ports
  • “Set it & Forget It” Remote Data Logging
  • Power: USB or Built-in Re-Chargeable Battery Pack
  • Multi-System Simultaneous Continuous Monitoring
  • Includes DataLight II Software and Labview Sample Code
  • NIST-Traceable/ISO17025 Accredited Calibration
  • Sample Rate Up to 100 Hz, Programmable
  • Made in the USA
  • Custom & OEM Inquiries Welcome

ILT1700 Features

Bench-Top Research "Blue Hazard" Radiance System

Features

  • Industry Standard Research Radiometer
  • Direct Reading in Scientific Notation
  • Best Price Performance
  • Unsurpassed Reliability for 15 years
  • Dynamic Auto Ranging – no lost samples in pulsed applications
  • 10 Decade Dynamic Range
  • 0.1 Percent Linearity
  • 40 Decade Integration Range
  • Light Integration up to 18 Years
  • 10 Calibration Factors in Memory
  • Made in the USA
  • Custom & OEM Inquiries Welcome!

 

SED033 Tblu SCS Response Curve

BLUE LIGHT HAZARD RADIANCE DETECTOR Specially configured for blue light hazard measurements with conformance to the human eye stimulation requirements. Calibrated for radiance measurements in W/cm2/sr.


Measurement Range: 5.56e-9  to 5.56e+0  W/cm2/sr
Hazard Spectral Range: 305 – 700 nm
Order part number: ILT1700 (meter), SED033/TBL/SC/R (detector)
Applications: This detector was designed to conform to the human eye stimulation requirements for making blue light hazard measurements. Equipped with our R Radiance/Luminance barrel for the required narrow field of view (± 0.75º). Calibrated to measure radiance directly in W/cm2/sr. 

SED SEL 033 Filter

 

 

 

 

 

R cosign

 

 

 

 

 

 

 

Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping.

 

To view additional Optical Radiation Hazard Light Measurement Systems, visit our application page here.