ILT1700,SED220/NS185

ILT1700

View ILT5000 Replacement
 

*** DISCONTINUED ***

Please see replacement ILT5000 product here.

The ILT1700 has been replaced the ILT5000 Radiometer which includes complimentary Datalight III software, faster measurement speeds, wireless data transmission, Iphone/Ipad application, internal data storage, a broader measurement range and more…


ILT5000 Specs


Benchtop Power (Watt) Measurement System

  • 10+ Decade Dynamic Range of Optical Analysis
  • Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
  • Wireless Communication, Built-in
  • User controlled or Auto: Range, Zero/Dark, Sample Rate
  • 4-20 mA Output
  • 15 pin D Sub and SMA sensor/input ports
  • “Set it & Forget It” Remote Data Logging
  • Power: USB or Built-in Re-Chargeable Battery Pack
  • Multi-System Simultaneous Continuous Monitoring
  • Includes DataLight II Software and Labview Sample Code
  • NIST-Traceable/ISO17025 Accredited Calibration
  • Sample Rate Up to 100 Hz, Programmable
  • Made in the USA
  • Custom & OEM Inquiries Welcome

 

ILT1700 Specs

 

Bench-Top Research Narrow Band Germicidal/Ozone Measurement System

  • Industry Standard Research Radiometer
  • Direct Reading in Scientific Notation
  • Best Price Performance
  • Unsurpassed Reliability for 15 years
  • Dynamic Auto Ranging – no lost samples in pulsed applications
  • 10 Decade Dynamic Range
  • 0.1 Percent Linearity
  • 40 Decade Integration Range
  • Light Integration up to 18 Years
  • 10 Calibration Factors in Memory
  • Made in the USA
  • Custom & OEM Inquiries Welcome!

 

 

SED 220NS Response Curve

Economical Narrow-Band Ozone/Germicidal Detector Configured to measure low intensity, ozone producing germicidal lamps at 185 nm where out of band rejection of 254 nm is not as critical.
Measurement Range: 5.00e-9 to 2.00e-3 Watts/cm2
Spectral Range:165 – 200 nm, Center wavelength: 185 nm
Dimensions: 58 mm x 42 mm diameter Order part number:ILT1700, SED220/NS185 (detector)
Applications: This detector has good spectral response at 185 nm but has also been fitted with a narrow bandwidth filter with a center wavelength at 185 nm, facilitating the measurement of the relatively low emissions at 185 nm from ozone producing mercury lamps where the strong emissions at the 254 nm mercury line are not present.

SED SEL 185 Detector

 

 

 

 

 

 

 

 

Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping.

For the latest meter specifications, data sheet, installation guide, tech notes and software, visit the ILT5000 page here.