ILT1700, SED623/SCS695/W

Bench-top research IR hazard measurement system

View ILT5000 Replacement
 

*** DISCONTINUED ***


The ILT1700 has been replaced the ILT5000 Radiometer which includes complimentary Datalight III software, faster measurement speeds, wireless data transmission, iPhone/iPad application, internal data storage, a broader measurement range and more…


ILT5000 Features


Bench-Top Research IR Hazard Measurement System

  • 10+ Decade Dynamic Range of Optical Analysis
  • Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
  • Wireless Communication, Built-in
  • User controlled or Auto: Range, Zero/Dark, Sample Rate
  • 4-20 mA Output
  • 15 pin D Sub and SMA sensor/input ports
  • “Set it & Forget It” Remote Data Logging
  • Power: USB or Built-in Re-Chargeable Battery Pack
  • Multi-System Simultaneous Continuous Monitoring
  • Includes DataLight II Software and Labview Sample Code
  • NIST-Traceable/ISO17025 Accredited Calibration
  • Sample Rate Up to 100 Hz, Programmable
  • Made in the USA
  • Custom & OEM Inquiries Welcome

ILT1700 Features

Bench-Top Research IR Hazard Measurement System

  • Industry Standard Research Radiometer
  • Direct Reading in Scientific Notation
  • Best Price Performance
  • Unsurpassed Reliability for 15 years
  • Dynamic Auto Ranging – no lost samples in pulsed applications
  • 10 Decade Dynamic Range
  • 0.1 Percent Linearity
  • 40 Decade Integration Range
  • Light Integration up to 18 Years
  • 10 Calibration Factors in Memory
  • Made in the USA
  • Custom & OEM Inquiries Welcome

 


 

Response Curve

INFRARED HAZARD DETECTOR Designed for taking accurate IR hazard measurements in W/cm2.

Measurement Range: 8.57e-5 to 9.52e-1 Watts/cm2
Hazard Spectral Range: 770 - 3000 nm
Order part number: ILT1700 (meter), SED623/SCS695/W (detector)


Applications: Thermopile-based detector with a quartz window providing the ideal sensitivity for making thermal irradiance hazard measurements. Please note, that by the very nature of thermopile-based detectors, this detector is heat sensitive and exposure to heat sources including the measurement source, should be kept to a minimum and the detector allowed to cool between readings.

 

Detector

 

 

 

 

 

 

 

 

cosign

 

 

 

 

 

 

 

 

 

Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping.

To view additional Optical Radiation Hazard light measurement systems, visit our application page here.