ILT1700, SED240/ACT5/W

Bench-top research Germicidal Light (UV disinfection) and Optical Radiation Hazard measurement system

View ILT5000 Replacement


*** DISCONTINUED ***

Please see replacement ILT5000 product.

The ILT1700 has been replaced the ILT5000 Radiometer which includes complimentary Datalight III software, faster measurement speeds, wireless data transmission, iPhone/iPad application, internal data storage, a broader measurement range and more.


ILT5000 Details

Research Germicidal Light (UV disinfection) & Optical Radiation Hazard Measurement System

  • 10+ Decade Dynamic Range of Optical Analysis
  • Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
  • Wireless Communication, Built-in
  • User controlled or Auto: Range, Zero/Dark, Sample Rate
  • 4-20 mA Output
  • 15 pin D Sub and SMA sensor/input ports
  • “Set it & Forget It” Remote Data Logging
  • Power: USB or Built-in Re-Chargeable Battery Pack
  • Multi-System Simultaneous Continuous Monitoring
  • Includes DataLight II Software and Labview Sample Code
  • NIST-Traceable/ISO17025 Accredited Calibration
  • Sample Rate Up to 100 Hz, Programmable
  • Made in the USA
  • Custom & OEM Inquiries Welcome

 

< Back to Germicidal & UV Disinfection System Table                    < Back to Optical Radiation Hazard System Table

ILT1700 Specs

Bench-Top Research Germicidal Light (UV disinfection) and Optical Radiation Hazard Measurement System

  • Industry Standard Research Radiometer
  • Direct Reading in Scientific Notation
  • Best Price Performance
  • Unsurpassed Reliability for 15 years
  • Dynamic Auto Ranging – no lost samples in pulsed applications
  • 10 Decade Dynamic Range
  • 0.1 Percent Linearity
  • 40 Decade Integration Range
  • Light Integration up to 18 Years
  • 10 Calibration Factors in Memory

 

Response Curve

EFFECTIVE GERMICIDAL DETECTOR

Configured with a spectral response weighted to match the IES Luckiesh and DIN standards for germicidal effectiveness.
Measurement Range: 5.00e-9 to 2.50e-3 effective Watts/cm2
Germicidal Spectral Range: 235 – 307 nm, calibration wavelength at 270 nm
Dimensions: 68 mm x 42 mm diameter
Order part numbers: ILT1700 (meter), SED240/ACT5/W (detector)
Applications: This detector has a weighted response and is specifically designed to measure the germicidal effectiveness of low-intensity, broad spectrum UV sources in accordance with the requirements within the IES Luckiesh and DIN standards.

Detector

 

 

 

 

 




ACTINIC OPTICAL RADIATION HAZARD DETECTOR

w_cosign

Specially designed with proprietary filtration for easy and accurate optical radiation hazard measurements in the UV Actinic range.

Measurement Range: 5.00e-9 to 2.50e-3 eff W/cm2
UV Actinic Hazard Spectral Range: 180 – 400 nm
Order part numbers: ILT1700 (meter), SED240/ACT5/W (detector)
Applications: This detector has been fitted with our proprietary UV Actinic Hazard filter giving the detector the required spectral response for taking UV optical radiation hazard measurements. Calibrated for readout in effective Watts per square centimeter. This system combination is capable of meeting UV hazard measurement standards that require instrumentation that can measure 0.1 microWatts per squared centimeter or better.

 

Filters and input optics are removable and may be ordered separately from detector assembly to allow filter and input optic swapping.

 

 

Please visit the ILT5000 product page to download the latest data sheet, instruction manual, software and other documents here.